Compliance with Standars En 81/1-2/20+A3
Drive Type Stepless Quick Gear Machine Gearless Machine (Machine with Ring or MRL)
Maximum Elevator Speed 4 m/sec
Group Work Up to 8 elevators
Number of Stops 64
Control Type Single Button Pickup Double Button Pickup
Serial Communication With Floor and Cabin
Cabin Position Information Magnetic Switches, Encoder System
Automatic Door Control Single Door, Double Door
Door Bridging N/A
Display Outputs 7 Segments, Gray/Binary Code LCD Output
Language Options Turkish, English, Russian, French, Dutch, Spanish, Swedish, Polish, German, Slovak.
  • Any kind of automatic door control
  • 1 piece of door control inputs and outputs in the revision box, 2 in the control panel
  • Built-in motor phase protection
  • Controlling ARCODE from any point with the hand-held terminal connected to the CANbus line
  • Leakage current protected cabinet and well feed fuses
  • Well lighting control with pulse current switch (with buttons from the top of the cabinet and from the bottom of the well)
  • Emergency alarm siren (with buttons from the top and bottom of the cabinet)
  • Special connections for safety circuits in the control panel, revision box and downhole box
  • Serial cabinet communication via CANbus line
  • One-to-one connection with the plug-in flat cable between the control panel and the revision box
  • Plug-and-play connection between cabinet operation panel and revision box with plug-in single cable
  • Serial communication via CANbus line or parallel floor connection with MSP16 card
  • Well CANbus line extending along the whole well, with plug cables from floor to floor
  • Plug-in connection with plug-in cable attached to the CANbus line for each floor well for floor control panel
  • Door contact installation extending along the whole well, with plug cables from floor to floor
  • Connection with plug-in cables for floor-to-door contact installation for floor door plug- lock contacts
  • Plug-in connection with downhole box via single cable
  • Independent door control according to stops with double door support
  • Recovery in floor at easy direction with 1 phase 220VAC UPS or battery group connection
  • Providing solutions to short floors thanks to direct stop feature